Technical Parameter
| Spec Model No | RUG-R-DC5V | RUG-R-DC12V | RUG-R-DC24V | RUG-R-DC48V |
| Input RV:Un | DC5V |
DC12V | DC/AC24V | DC/AC48V |
| Input RV Range(Un) | +20%/-10% | ±20% | ±20% |
±20% |
| Un Input Current | <33mA | <16mA | <18mA |
<10mA |
| pull-in voltage | ≧75%Un |
|||
| Release voltage | ≦5%Un |
|||
| Response time(Un ) | ≤8ms | ≤8ms |
≤8ms |
≤8ms |
| releasing time(Un) | ≤5ms | ≤6ms |
≤5ms |
≤5ms |
| Output maximum switching voltage | 250VAC/30VDC |
|||
| Maximum switching current (negative resistance | ) 6A | |||
Max Switching Power |
1500VA/180W |
|||
| maximum operating frequency | 360times/h |
|||
| Contact material/contact form | Silver alloy/1open end |
|||
| Input voltage withstand | 1800VAC 1min |
|||
| Output end withstand voltage | 1000VAC 1min |
|||
Surge immunity |
2KV |
|||
| EFT | 4KV |
|||
| Mechanical life/electrical life | 1*107/6*104(6A 250VAC/30VDC,resistance load 85℃,on 1s off 9s) | |||
| Ambient temperature | -40℃~+85℃ |
|||
| storage temperature | -40℃~+85℃ |
|||
| Working Relative Humidity | 5%~85% |
|||
| Working Altitude | <2000m |
|||
| Pollution Grade | 2 |
|||
| Installation mode/connection mode | U/G Din rail mounting/M3 | |||
| Wire Range | IEC:0.2~6mm2(Sol),0.2~4mm2(Str),24~10AWG | |||
| RUG-R-DC60V | RUG-R-DC110V | RUG-R-DC220V | |
| Input RV:Un | DC/AC60V | DC/AC110V | DC/AC220V |
| Input RV Range(Un) | ±20% |
||
| Un Input Current | <10mA | <6mA |
<6mA |
| pull-in voltage | ≧75%Un |
||
| Release voltage | ≦5%Un |
||
| Response time(Un ) | ≤8ms |
≤8ms |
≤8ms |
| releasing time(Un) | ≤6ms |
≤4ms |
≤4ms |
| Output maximum switching voltage | 250VAC/30VDC |
||
| Maximum switching current (negative resistance | ) 6A | ||
Max Switching Power |
1500VA/180W |
||
| maximum operating frequency | 360times/h |
||
| Contact material/contact form | Silver alloy/1open end |
||
| Input voltage withstand | 1800VAC 1min |
||
| Output end withstand voltage | 1000VAC 1min |
||
Surge immunity |
2KV |
||
| EFT | 4KV |
||
| Mechanical life/electrical life | 1*107/6*104(6A 250VAC/30VDC,resistance load 85℃,on 1s off 9s) | ||
| Ambient temperature | -40℃~+85℃ |
||
| storage temperature | -40℃~+85℃ |
||
| Working Relative Humidity | 5%~85% |
||
| Working Altitude | <2000m |
||
| Pollution Grade | 2 |
||
| Installation mode/connection mode | U/G Din rail mounting/M3 | ||
| Wire Range | IEC:0.2~6mm2(Sol),0.2~4mm2(str),24~10AWG | ||
Dimension
Layout(unit:mm)

Diagram of electrical connection
Caution
●The company shall be responsible for the quality problems caused by unauthorized disassembly of the product;
●Please do not debug the characteristics of the terminal at willing. The factory will not be responsible for the product quality problems caused by this.
Product detail pictures:
Related Product Guide:

New Products
Terminal Blocks
Electronic Controls
Heavy Duty Connector
PV & ESS Connector
Safety and Security
Accessories
Company News
Industry News
Exhibition News
Optical Storage System
Industrial Automation
Power Industry
New Energy Vehicles
Railway Transport
Electronic Communication
IQ Lab
Download Center
Exhibitions
Recruitment