RUG-O_Optocouple Functional Terminal Series

Short Description:

● Low signal loss at the control end
● High switching frequency
● No contact jitter
● Not afraid of vibration
● Not affected by location
● No mechanical parts
● Long life
● High insulation voltage

  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • Product Detail

    Product Tags

    Technical Parameter

    Prod.Desp. Din Rail Functional Terminal Block-RUG-O Series Optocoupler
    Item No. RUG-O-110(220)VDC-L-50mA;RUG-O-110(220)VDC-H-50mA;      RUG-O-110(220)VAC-L-50mA;RUG-O-110(220)VAC-H-50mARUG-O-5(12)(24)(48)(60)(110)(220)VDC-L-100mA;                   RUG-O-5(12)(24)(48)(60)(110)(220)VDC-H-100mA

    RUG-O-24(110)(220)VAC-L-100mA;                                          RUG-O-24(110)(220)VAC-H-100mA

    RUG-O-5(12)(24(48)(60)(110)(220)VDC-L-200(300)(500)mA;    RUG-O-5(12)(24(48)(60)(110)(220)VDC-H-200(300)(500)mA

    RUG-O-5(12)(24(48)(60)(110)(220)VAC-L-200(300)(500)mA;    RUG-O-5(12)(24(48)(60)(110)(220)VAC-H-200(300)(500)mA

    RUG-O-5(12)(24)(48)(60)(110)(220)VDC-L-1(2)(5)A;                RUG-O-5(12)(24)(48)(60)(110)(220)VDC-H-1(2)A

    RUG-O-24(48)(60)(110)(220)VAC-L-1(2)A;                               RUG-O-24(48)(60)(110)(220)VAC-H-1(2)A

    Material: PA/Brass
    Thickness(mm) 6.2
    Width(mm) 59.3
    Depth(mm) 65.8
    Connection Screw(M3)
    Cross Section(mm2) 0.2--6.0
    Rated Voltage(V) 5/12/24/48/60/110/220
    Rated Current(A) 50mA/100mA/200mA/300mA/500mA/1A/2A/5A
    Strip Length(mm) 9-10
    Flammability: V0
    Standard IEC60947-5-1;GB/T14048.5
    DIN Rail: U
    Color: Grey
    Operation Temp. -25℃--+70℃
    Area Humility 5%-95%
    IP Level IP20
    Surge Anti-interference 2KV
    Group Pulse Anti-Interference 4KV
    ESD Anti-interference 8KV
    Certificate CE
    Feature:
    With the continuous improvement of the degree of automation, the isolation between control and field circuits has increasingly shown importance. As the
    core of the automatic control system, the control unit must be reliably isolated from the sensors and actuators to avoid interference. The company’s
    optocoupler module can perform the above functions well, and can also be used as a peripheral device for process control to control, signal and
    adjust the interface components of the connection between the device. Suitable for different voltage and power ranges, etc. Since photoelectric coupling
    can provide the necessary safety interface and has the following characteristics, it is widely used in actual use.