RSKP Flanged Nylon Waterproof Joint

Short Description:

● Material :PA6/PA66,V0 Level Acc. to UL94
● Sealing Material: EPDM,NBR,SI
● IP Grade:clamping range,O-ring,IP68
● Temperature Limited:-40℃-100℃,short- term120℃
● Products Feature:The main body and the flange base can be separated, and using the screw connection is tighter and more reliable.

Protecting connection safe by using improved protective sealing.

 


  • RSKP Flanged nylon cable gland: Flanged cable gland with better installation
  • Product Detail

    Product Tags

    Technical Parameter

    Item No.

    Cores xOD(Φ)mm

    Mounting Hole Distance

    (L1)mm  (L2)mm

    Spanner (SW1)mm

    Holing (mm)

    Color

    RSFP-53x28A-2x5.5

    2x5.5

    53     28

    27

    Φ12.2-Φ12.4

    BK/GY

    RSFP-53x28A-1x7+1x5.5

    1x7+1xx5.5

    53     28

    27

    Φ16.2-Φ16.4

    BK/GY

    RSFP-53x28A-2x7

    2x7

    53     28

    27

    Φ16.2-Φ16.4

    BK/GY

    Cable glands are defined as ‘mechanical cable entry devices’ which are used in conjunction with cable and wiring for electrical, instrumentation & control, and automation systems, including lighting, power, data and telecoms.

    The main functions of the Cable Gland are to act as a sealing and terminating device to ensure the protection of electrical equipment and enclosures, including the provision of:

    • Environmental protection – by sealing on the outer cable sheath, excluding dust and moisture from the electrical or instrument enclosure.
    • Earth continuity – in the case of armoured cables, when the cable gland has a metallic construction. In this case cable glands may be tested to ensure that they can withstand an appropriate peak short circuit fault current.
    • Holding force – on the cable to ensure adequate levels of mechanical cable ‘pull out’ resistance.
    • Additional sealing – on the part of the cable entering the enclosure, when a high degree of ingress protection is required.
    • Additional environmental sealing – at the cable entry point, maintaining the ingress protection rating of the enclosure with the selection of applicable accessories dedicated to performing this function.

    Cable glands can be constructed from metallic or non-metallic materials (or a combination of both) which may also be resistant to corrosion as determined by selection to a standard, or by corrosion resistance tests.

    When used in explosive atmospheres in particular, it is crucial that cable glands are approved for the selected type of cable and that they maintain the level of protection of the equipment to which they are attached.




  • Previous:
  • Next: